Terms & Policies


Hall Effect Sensors

Vane Sensors


 
Life-time Warranty
No questions asked
Replacement / Refund


Consult us about
our Best Price
Guarantee!

 

Hall Current Sensor HIEM-DC-2000K

For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).

Datasheet PDF

Electrical Data

TYPE DC-

300K

DC-

500K

DC-

600K

DC-

1000K

DC-

2000K

parameter sign
Primary nominal (r.m.s. current) IPN 300A 500A 600A 1000A 2000A
Primary current measuring range IP 0~

600A

0~

1000A

0~

1200A

0~

2000A

0~

3000A

Secondary nominal RMS voltage VSN 4V
Supply voltage VC ±12V~±15V
Zero offset voltage

@IPN =0,

TA = 25°C

V0 within±20mV
Thermal drift of offset voltage@

IPN =0

 

VOT

 

within±1mV/°C

Linearity of VSN at IPN =F.S εL within±1%F.S
Response time Tr <7μs
R.m.s. voltage for AC isolation test Vd 6KV/50Hz/1min
Accuracy X <±1%F.S
Frequency bandwidth f DC~20KHz(-3dB)
Current consumption Ic <20mA
Load resistance RL ≥1 kΩ
Ambient operating temperature Ta -10~+70°C E:-40~+85°C
Ambient storage temperature Ts -25~+85°C E:-45~+105°C

Dimension (mm)

Features

  1. Opened loop (compensated) multirange current sensor using the Hall effect
  2. Fast response time
  3. Excellent linearity for exact
  4. Wide frequency range
  5. No insert losses

Applications

  1. AC variable speed drives and serve motor drives
  2. Uninterruptible Power Supplies (UPS)
  3. Power supplies for welding applications
  4. Switched Mode Power Supplies

Connection diagram