Hall Current Sensor HIEM-DC-600B

For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).

Datasheet PDF

Electrical Data

TYPE DC-

500B

DC-

100B

DC-

200B

DC-

300B

DC-

600B

parameter sign
Primary  nominal (r.m.s. current) IPN 50A 100A 200A 300A 600A
Primary current measuring range IP 0~

±150A

0~

±300A

0~

±600A

0~

±700A

0~

±800A

Secondary nominal RMS voltage VSN 4V±1% at IPN (RL=10KΩ)
Supply voltage VC ±15V±5%
Zero offset voltage

@ IPN =0,

TA = 25°C

V0 within±30mV
Thermal drift of offset voltage

@IPN =0

VOT within±1mV/°C
Linearity of VSN at IPN =F.S εL within±1%F.S
Response time Tr <7μs
R.m.s. voltage for AC isolation test Vd 2.5KV/50Hz/1min
Ambient temperature operating Ta -10~+70°C E:-40~+85°C
Ambient temperature storage Ts -40~+85°C E:-55~+125°C

Dimension (mm)

Features

  1. Opened loop (compensated) multirange current sensor using the Hall effect
  2. Small size and space saving
  3. Low power consumption
  4. Flexible way of installment
  5. Low insertion losses

Applications

  1. AC variable speed drives and serve motor drives
  2. Uninterruptible Power Supplies (UPS)
  3. Battery supplied applications
  4. Communications supplies applications

Pin Identification

Pin Function Function
1 +15v +15v
2 -15v -15v
3 VOUT VOUT
4 0V 0V